Properties
- Extended open time
- Thixotropic
- Gap filling
Application
For joining pipes, sockets and fittings with interference fit and loose fit (gap filling) in pressure and drainage systems. Extremely suitable for large diameters and at higher temperatures (> 35 °C). Suitable for diameters ≤ 800 mm. Max. 16 bar (PN 16). Maximal tolerances 0.8 mm diametrical clearance / 0.2 mm press fit. Suitable for e.g. pipe systems conforming to EN 1329, 1452, 1453, 1455 and ISO 15493 (PVC).
Handling
Before use
Do not use in temperatures ≤ +5 °C.
Indication of the number of joints per 1 L:
During use
1. Cut pipes square, chamfer edges and deburr. 2. Clean surfaces with acetone and a clean, lint-free cloth. 3. Apply adhesive rapidly and evenly lengthways on both surfaces (pipe thickly, socket thinly). 4. Assemble joint immediately. Remove excess adhesive. Do not load the joint mechanically for the first 10 minutes. Close packaging immediately after use.
After use
Remove adhesive stains with acetone and a clean, lint-free cloth.