PVC Kit

Thixotropic rigid PVC cement

PVC Kit

What is it?

Back to top

What does it do?

Suitable for:

For joining pipes, sockets and fittings with interference fit and loose fit (gap filling) in pressure and drainage systems. Extremely suitable for large diameters and at higher temperatures (> 35°C). Suitable for diameters ≤ 800 mm. Max. 16 bar (PN 16). Maximal tolerances: 0.8 mm diametrical clearance / 0.2 mm press fit. Suitable for e.g. pipe systems conforming to EN1329, 1452, 1453, 1455 and ISO15493 (PVC).

Back to top

Getting started

Before use:

Working conditions

Do not use in temperatures ≤ +5°C.

During use:

Directions for use

1. Saw off pipes squarely, chamfer and deburr. 2. Clean adhesive surfaces with acetone and a clean, lint-free cloth. 3. Apply adhesive rapidly and evenly lengthways to both bonding surfaces (pipe thickly, sleeve thinly). 4. Assemble joint immediately. Remove excess adhesive. For the first 10 minutes, do not load the joint mechanically. Properly close the container immediately after use.

After use:

Stains/residue

Remove adhesive stains with acetone and a clean, lint-free cloth.

Back to top